Quick Links:        Home        Demo        FAQ        Update

 

Updates:

Please follow link below to download Window Glass Design 5 update.
       Window Glass Design Software 5
 
All revisions are included in the latest update.
 

Revision

Description

Date

  

1.31

#

Corrections

1 Corrected user interface error with air spaces for triple gazed IG units.  *Standard and Deluxe versions only*

1/24/17

  

1.30

#

Corrections

1 Corrected and updated the Eastman Glass Charts *Standard and Deluxe versions only*
2 Added E 1300 2012 to the standard selection list

1/25/16

  

1.29

#

Corrections

1 Non-Factored Load charts have been expanded for 4-sided supported lites.

10/17/14

  

1.26

#

Corrections

1 Short duration load deflection on result printouts were incorrectly displaying "-111 mm" in some design cases.

2/21/14

  

1.25

#

Corrections

1 Theoretical Load Share values for IG units have been locked to monolithic glass design only.  This is to keep the values in line with the publication it was based upon: "The Structural-Mechanics Behavior of Insulating Glass Units" by C. David Chou, Joseph E. Minor, and C.V. Girija Vallabhan.

11/13/12

  

1.24

#

Corrections

1 The maximum thickness for 3-sided supported laminate should be 3/4 in. (19 mm). 

10/11/12

  

1.23

#

Corrections

1 Long duration load deflection on Results screen was incorrectly displaying "-111 mm" in some design cases.

8/29/12

  

1.22

#

Corrections

1 Editorial changes to the Load Converter tool. 

8/21/12

  

1.21

#

Corrections

1 The tables for Solutia's Saflex® VS and Vanceva® VS have been corrected.  This affects Standard and Deluxe users only. 

1/4/12

  

1.20

#

Corrections

1 The wrong thickness was being used for range calculations when 1-sided or 2-sided supported frames were chosen.
2 The interval for width and height range was not being restored correctly from a saved file. 

10/19/11

  

1.19

#

Corrections

1 Fixed some 'outliers' in the 4-sided, monolithic deflection polynomial. 

10/3/11

  

1.18

#

Corrections

1 Corrected the laminate thickness display for range value reports. 

9/13/11

  

1.17

#

Corrections

1 Corrected title error for triple IG unit results display.
2 For non-US language settings the deflection results were calculating incorrectly.  This is an error in interpreting the comma as a decimal or visa versa depending on the case.  This 'translation' has been corrected. 

9/7/11

  

1.16

#

Corrections

1 Asymmetric (monolithic/laminated) double IG units were calculating incorrect load share multipliers in some configurations.

7/8/11

  

1.15

#

Corrections

1

Correction to Triple IG unit logic.  In some cases, the incorrect Load Resistance was chosen.  

6/20/11

  

1.14

#

Corrections

1

New interlayer options by Solutia:  Saflex® VS, Saflex® PVB,  Vanceva® Colors, Vanceva® VS

The update affects Standard and Deluxe users only.  User must be in "Plus" mode to view interlayer options.   

6/9/11

  

1.13

#

Corrections

1 Added Solutia Logo to Solutia interlayer NFL Charts and other minor edits. 

2

In Max Stress tool, added check for long dimension and short dimension.  (If entered incorrectly, the program would freeze up.)

6/7/11

  

1.12

#

Corrections

1

When selecting a different edge support or switching from laminate to monolithic, the glass thickness selection remains the same. 

3/11/11

  

1.11

#

Corrections

1

DuPont Interlayer selection now working in Multiple Glazing Input

3/7/11

  

1.10

#

Corrections

1

Multiple Glazing Input error when changing units, fixed

3/2/11

  

1.09

#

Corrections

1

Multiple Glazing Input fixed

2/28/11

  

1.08

#

Corrections

1

If using Automatic Thickness Calculator, the display in the results window would show the same answer for both thicknesses in an IG unit, this has been corrected
2 When file saving, the default was the 2004 program instead of the version 5.
3 Load share factors for non-symmetric, long duration, double IG units was not calculating correctly.  This has been fixed

2/3/11

  

1.07

#

Corrections

1

Network Users - Corrected reference path to network user log.

1/12/11

  

1.06

#

Corrections

1

Corrected refresh error when using laminated glass in the Advanced Glazing input.  Input now displays interlayer options.

2

"in." has been changed to "mm" when using SI units option

11/18/10

  

1.05

#

Corrections

1

If display settings are set to 125%, 150% or the dpi settings are increased, the input display will adjust accordingly

10/21/10

  

1.04

#

Corrections

1

And another correction to date recognition for non US-English settings

2

When printing the "Details" report from "Print Preview", the report was not displaying the correct values.  This has been fixed. 

10/12/10

  

1.03

#

Corrections

1

Another correction to date recognition for non US-English settings

10/11/10

  

1.02

#

Corrections

1

Corrected "footer" error when print or print preview is selected

10/6/10

  

1.01

#

Corrections

1

Corrected long duration load deflection display. 

2

Corrected date recognition error when US-English region settings are not being used.

9/23/10

 

 

                                                                                Home   | Products   | Tech Support   | Company | Information 

                                                                                  All Rights Reserved.  © 2004 Standards Design Group, Inc.
                                                                                      Legal Information